The ZAND-AIR 100P Air Purification System is a portable unit, specifically developed to meet the demands in anatomical pathology and forensic laboratories where formalin and other toxic hydrocarbons are prevalent. They are effective in areas where pathology chemicals are used and regular refilling for automated and manual slide stainers and processors is required.
The ZAND-AIR Four Step Air Purification Process of the 100P
Step One. Activated Carbon Filter adsorbs toxic chemicals and gases.
The FRONT POSITION Activated Carbon Filter, is a specially formulated mixture of proprietary compounds selected to adsorb all VOCs and CACs in the laboratory environment. Scientifically formulated adsorption media ((including zeolite and potassium permanganate) adsorbs organic hydrocarbons, formaldehyde used in the laboratory.
Step Two: Higher Adsorption of VOCs and CACs
A second Activated Carbon Filter increases the ‘dwell time’ providing a higher adsorption of VOCs and CACs.
Step Three:. Photo-Catalytic Oxidation Destroys Toxic Chemicals and Eliminates Odours from the Air
Photo-Catalytic-Oxidation converts toxic compounds into benign constituents such as water (H2O) and carbon dioxide (CO2). The catalyst is such that it does not wear out or lose its effectiveness as a result of its actions.
Step Four. Ultraviolet Light
Ultraviolet technology combined with Photo-Catalytic-Oxidation is an important feature of this purification system since germs are easily spread from person to person and by central heating and air-conditioning systems. We offer a special attachment for personnel working in small “Cut-up” and “cover slipping” areas. An acrylic cover over the work area directs airflow in a downward direction and contains fumes coming from open containers. Cat No. ZA 100P-FH
Technical Specifications: 100P
Dimensions: | 21.5″w X 18″h X 8″d (55cm X 46cm X 20cm) |
Weight: | 23 lbs. (10.43 kg) |
Max Air Flow: | 265 cfm /7.5 m3 per minute |
Max Watts: | 110 watts |
Voltage: | 120v – 60hz /220v – 50hz |
Blower: | Reversed – curved motorized impeller |
Catalyst: | Metal oxides |
U.V. Range: | 254 nm (produces no ozone) |
Gas Adsorption: | Two stage activated carbon media |
Application: | 2,000 sq. feet max./185 sq. meters |
Service: | U.V. Lamps -1 year, Filters – 6 months |
Warranty: | 2 year limited warranty on all components excluding light and filters |
Catologue Number ZA 100P
Spares for ZA 100P
Filter for the zIVF-AIRe™100P (Two stage Carbon) Cat No. ZA RK401
UV Germicidal Lamp for zIVF-AIRe 100C & 100P Cat No ZA RK203